tic outdoor speaker cable wiring
how to install outdoor speaker cable
simple outdoor speaker installation cable wiring solution
tic installation cable guidelines
Below you will note basic guidelines for outdoor speaker cable in the form of charts for outdoor speaker burial cable runs with allowances for resistance down the line and or power / voltage drops incurred. Besides power consumption loss, resistance in a cable run has a very detrimental effect upon sound quality and output power.
While the guides below are generally useful for outdoor speaker burial cable it should also be noted that specific, local installation conditions, connections integrity and wire quality including copper quality content of the cable itself, all have an effect upon resistance down the line and therefore your ultimate performance characteristics.
outdoor speaker burial cable wiring specifics

According to the consumerreports.org outdoor speaker wireless models are not recommended; "Among the wireless sets we tested, they were prone to interference from devices such as cordless phones, microwave, resulting in static, hissing or clicking". They have high failure rate for a frequency transmitter, their sound quality is AM radio comparable and made of fragile plastics components which can easily break."
outdoor speaker cable based upon impedance testing 8 Ohm units
| Recommended Cable Gauge (g) Vs. Length of Cable Run (m + Ft.) | |||||
| 15m ±50 Ft. |
30m ±100 Ft. |
45m ±150 Ft. |
60m ±200 Ft. |
75m ±250 Ft. |
100m ±300 Ft. |
| 18g | 16 / 14g | 14 / 12g | 12g | 12 /10g | 10g |
70v in-line distribution cable wire run gauges
recommended maximum wire run for a certain power rate and wire gauge
| Wire Gauge | 5 watt | 10 watt | 15 watt | 30 watt | 50 watt | 100 watt | 200 watt |
| 16 | 10,000 ft | 7,000 ft | 4,600 ft | 2,300 ft | 1.400 ft | 700 ft | 350 ft |
| 18 | 9,000 ft | 4,500 ft | 2,800 ft | 1,400 ft | 830 ft | 415 ft | 205 ft |
| 20 | 5,500 ft | 2,700 ft | 1,800 ft | 900 ft | 540 ft | 270 ft | 135 ft |
| 22 | 3,400 ft | 1,700 ft | 1,100 ft | 550 ft | 330 ft | 115 ft | 60 ft |
| 24 | 2,100 ft | 1000 ft | 700 ft | 350 ft | 210 ft | 105 ft | 50 ft |
power line (mains power) cable calculator
| Total System Amperage Drawn | Up To 4 ft. | Up To 7 ft. | Up To 10 ft. | Up To 13 ft. | Up To 16 ft. | Up To 19 ft. | Up To 22 ft. | Up To 28 ft. |
| 0-20A | 14 ga. | 12 ga. | 12 ga. | 10 ga. | 10 ga. | 8 ga. | 8 ga. | 8 ga. |
| 20-35A | 12 ga. | 10 ga. | 8 ga. | 8 ga. | 6 ga. | 6 ga. | 6 ga. | 4 ga. |
| 35-50A | 10 ga. | 8 ga. | 8 ga. | 6 ga. | 4 ga. | 4 ga. | 4 ga. | 4 ga. |
| 50-65A | 8 ga. | 8 ga. | 6 ga. | 4 ga. | 4 ga. | 4 ga. | 4 ga. | 2 ga. |
| 65-85A | 6 ga. | 6 ga. | 4 ga. | 4 ga. | 2 ga. | 2 ga. | 2 ga. | 0 ga. |
| 85-105A | 6 ga. | 6 ga. | 4 ga. | 2 ga. | 2 ga. | 2 ga. | 2 ga. | 0 ga. |
| 105-125A | 4 ga. | 4 ga. | 4 ga. | 2 ga. | 0 ga. | 0 ga. | 0 ga. | 0 ga. |
| 125-150A | 2 ga. | 2 ga. | 2 ga. | 0 ga. | 0 ga. | 0 ga. | 0 ga. | 00 ga. |
| The above chart shows wire gauges to be used, if no less than .5 volt drop is accepted. If aluminum wire or tinned wire is used, the gauges should be of an even larger size to compensate. Cable gauge size calculation takes into account terminal resistance. Wire gauge recommendations based on IASCA guidelines. |
||||||||
wheelock's speaker calculator
| Wheelock's Speaker Calculator |
| The objective of this program is to provide an easy way to determine wire lengths, quantity of speakers and amplification needed for commercial paging systems. The Wheelock Speaker Calculator is broken into 4 modules. |
|
| Install Speaker Calculator from the Web |
| Download Speaker Calculator in one .zip file |
| http://www.wheelockinc.com/technical_support/software.htm |
| Wheelock Speaker Calculator a program to provide an easy way to determine wire lengths, quantity of speakers and amplification needed for commercial paging systems. |
Contact
Please Contact us at TIC Corporation where we will be happy to answer any questions you may have.
TIC Corporation will in no way be held responsible for the improper, misuse or unsecured installation of its products. Any and all damage, injury or liability arising from the installation or use of TIC products is the sole responsibility of the original purchaser and final installers.
TIC cannot be held responsible for typographical errors contained within company literature or this website. Pricing and availability subject to change without notice, when placing an order the customer accepts and agrees to all TIC general terms and conditions. Note on pictures shown; all pictures shown for web purposes are low resolution. All TIC products shown are expected to improve or exceed their visual characteristics as shown.